Power Divider Question

Post by spareparts »

I have a UHF repeater that has less then stellar in-building coverage as the antenna is on the roof. We would like to delploy a Radiax system, using a power divider (25% to radiax, 75% to the antenna)

Kathrein-Scala has several models, but they are 50% to each port. Any ideas on a manufacturer who can produce a 25/75 divider?
tvsjr
Posts: 4118
Joined: Fri Nov 28, 2003 9:46 am

Re: Power Divider Question

Post by tvsjr »

Call EMR... I think they can build custom dividers like that.
User avatar
wavetar
Administrator
Posts: 7340
Joined: Sun Sep 09, 2001 4:00 pm

Re: Power Divider Question

Post by wavetar »

We had Sinclair build us custom power dividers in the past. They do work as advertised, but be aware they have fairly high loss compared to the 50/50 splitters.

Todd
No trees were harmed in the posting of this message...however an extraordinarily large number of electrons were horribly inconvenienced.

Welcome to the /\/\achine.
User avatar
Wowbagger
Aeroflex
Posts: 1287
Joined: Tue Dec 10, 2002 10:46 am

Re: Power Divider Question

Post by Wowbagger »

spareparts wrote:I have a UHF repeater that has less then stellar in-building coverage as the antenna is on the roof. We would like to delploy a Radiax system, using a power divider (25% to radiax, 75% to the antenna)
Why are you making it hard on yourselves? Go for a 50/50 split - those are easy to design a power divider for.

Remember, the difference between 50% and 75% is only an increase of 1.7dB. One S unit is nominally 6 dB.
This is my opinion, not Aeroflex's.

I WILL NOT give you proprietary information. I make too much money to jeopardize my job.

I AM NOT the Service department: You want official info, manuals, service info, parts, calibration, etc., contact Aeroflex directly, please.
User avatar
nmfire10
Batboard $upporter
Posts: 4109
Joined: Sat Jun 29, 2002 4:41 pm

Re: Power Divider Question

Post by nmfire10 »

I think you'd be better off with 50/50 anyway. Go for that.
"I'll eat you like a plate of bacon and eggs in the morning. "
- Some loser on rr.com

eBay at it's finest:
Me: "What exactly is a 900Mhz UHF CB?"
Them: "A very nice CB at 900Mhz speed!"

:-?
Will
Posts: 6823
Joined: Tue Sep 04, 2001 4:00 pm

Re: Power Divider Question

Post by Will »

Why do you need an antenna on top of the building to talk inside the building???

Move the repeater to one third building elevation, feed 50% up to
the top floor, and the other 50% down into the basement.
Don't forget the load on each end of the Radiax.
spareparts
Batboard $upporter
Posts: 502
Joined: Fri Dec 19, 2003 5:33 pm

Re: Power Divider Question

Post by spareparts »

The system needs to cover the town around the building, and provide in-building coverage.
User avatar
N4DES
was KS4VT
Posts: 1233
Joined: Thu Dec 25, 2003 7:59 am
What radios do you own?: APX,XTS2500,XTL2500,XTL1500

Re: Power Divider Question

Post by N4DES »

You might gain more by changing the antenna to one that has built-in downtilt (.05 or 1 degree) rather than installing radiax. You also won't loose your system gains when trying to cover areas other than the building. Here is a UHF antenna that has 3 degree DT:

http://www.rfsworld.com/websearch/DataS ... ?q=455DT3D
Will
Posts: 6823
Joined: Tue Sep 04, 2001 4:00 pm

Re: Power Divider Question

Post by Will »

KS4VT wrote:You might gain more by changing the antenna to one that has built-in downtilt (.05 or 1 degree) rather than installing radiax. You also won't loose your system gains when trying to cover areas other than the building. Here is a UHF antenna that has 3 degree DT:

http://www.rfsworld.com/websearch/DataS ... ?q=455DT3D
WAY too much gain.. use a unity gain true dipole antenna. That will help to fill in below the antenna. We use the Comtelco BSL450-C for 450 to 470 or the BSL450-BC for 445-465.

Put the repeater near the one half height of the building, 50% up the radiax with the Comtelco BSL450-C on the end, the other 50% down the radiax to the basement.

One building we did has a 10db yagi antenna on 462 pointed down inside the building from a couple of floors below the top. It works well in the building and even out a couple of miles. 13 story building IIRC.
User avatar
N4DES
was KS4VT
Posts: 1233
Joined: Thu Dec 25, 2003 7:59 am
What radios do you own?: APX,XTS2500,XTL2500,XTL1500

Re: Power Divider Question

Post by N4DES »

I only used that antenna as an example. I have no idea how big the "town" is to cover so I SWAG'ed it.
SlimBob
Posts: 911
Joined: Thu Dec 18, 2003 11:38 am

Re: Power Divider Question

Post by SlimBob »

Just use a -10dB directional coupler. Then it's 10W in the building and 90W out the antenna...

A -20dB directional coupler might even be just as effective, and potentially easier to source. Route the output to a small amp and you're in business. If you transmit 100W, the coupler will shear off 1W, leaving 99W to be sent up to the roof, and the 1W signal can be used to drive a 5-10W amp for inbuilding.

I would think that 1W into a piece of radiating coax should be enough. 5W ought to be.
User avatar
N4DES
was KS4VT
Posts: 1233
Joined: Thu Dec 25, 2003 7:59 am
What radios do you own?: APX,XTS2500,XTL2500,XTL1500

Re: Power Divider Question

Post by N4DES »

SlimBob wrote:Just use a -10dB directional coupler. Then it's 10W in the building and 90W out the antenna...

A -20dB directional coupler might even be just as effective, and potentially easier to source. Route the output to a small amp and you're in business. If you transmit 100W, the coupler will shear off 1W, leaving 99W to be sent up to the roof, and the 1W signal can be used to drive a 5-10W amp for inbuilding.

I would think that 1W into a piece of radiating coax should be enough. 5W ought to be.
But you would loose the ability to use the radiax section for increased talk-back because the proposed 5-10 watt building amp is not bi-directional. You may hear the call but may have one heck of the time responding back.
SlimBob
Posts: 911
Joined: Thu Dec 18, 2003 11:38 am

Re: Power Divider Question

Post by SlimBob »

KS4VT wrote: But you would loose the ability to use the radiax section for increased talk-back because the proposed 5-10 watt building amp is not bi-directional. You may hear the call but may have one heck of the time responding back.
True enough.
Dan562
Posts: 533
Joined: Mon Aug 23, 2004 7:30 pm
What radios do you own?: Kenwood, Yaesu, ICOM, Motorola

Re: Power Divider Question

Post by Dan562 »

Try Scala Electronic Corporation in Medford, Oregon. Telephone # 503 - 779 - 6500, they manufacture several versions:

PD2 - 55 50% - 50%
PD2 - 72 75% - 25%
PD2 - 91 90% - 10%

I've used all three of these with Radiax in the Radio Paging and Two-way Radio applications with great success.

Dan
Jason
Posts: 802
Joined: Mon Oct 08, 2001 4:00 pm

Re: Power Divider Question

Post by Jason »

Nice to see you back on the board dan, you are always a wealth of information!
spareparts
Batboard $upporter
Posts: 502
Joined: Fri Dec 19, 2003 5:33 pm

Re: Power Divider Question

Post by spareparts »

Dan562 wrote:Try Scala Electronic Corporation in Medford, Oregon. Telephone # 503 - 779 - 6500, they manufacture several versions:
Thanks! Will call Monday AM
spareparts
Batboard $upporter
Posts: 502
Joined: Fri Dec 19, 2003 5:33 pm

Re: Power Divider Question

Post by spareparts »

Ended up ordering a SP-12974 – PDL2/91/50 Power from Kathrein Scala Corporation. $440.00
Dan562
Posts: 533
Joined: Mon Aug 23, 2004 7:30 pm
What radios do you own?: Kenwood, Yaesu, ICOM, Motorola

Re: Power Divider Question

Post by Dan562 »

Whoa, those Power Dividers have certainly increased in price. They used to cost about $100.00 each, talk about inflated prices Geesh! They must have spoken to the financial people at the Motorola's Schaumburg Campus!

Well at you were able to get what you needed ..... a Gold Plated RF Power Divider. :lol:

Dan
spareparts
Batboard $upporter
Posts: 502
Joined: Fri Dec 19, 2003 5:33 pm

Re: Power Divider Question

Post by spareparts »

Dan562 wrote:Well at you were able to get what you needed ..... a Gold Plated RF Power Divider.
Per Don Bennett @ Kathrein-Scala, it's just gold anodized ......